Télécharger Imprimer la page

Zenacasa AL-130 Manuel D'instructions page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
ERROR CODES DISPLAY DURING DETECTION
If one of the following error codes is displayed on the screen during detection, you can refer to the
table below to resolve the problem.
The main cause of repeated errors in detection is incorrect insertion of banknotes. Please check
first of all that you place the note you wish to insert flush to the right-hand side of the device, as
shown in section n°4.
If the errors persist, you can recalibrate the detectors by following the steps below:
Before turning on the mahine, hold down the CUR/DIR button and press the ON/OFF button: the
screen will go into calibration mode.
Open the hopper, prepare a piece of white paper and fold it so that it fits in the tray and covers
the detectors. Close the tray over the piece of paper.
Hold down the REP/CLR button until the display shows the beginning of calibration. Wait until
the calibration is finished, then remove the piece of paper and turn off the machine.
Turn on the machine normally with the ON/OFF button.
ERROR
CODE
E1
E2/E3
E4/E5
E6
E7
E10
E11/ E15/ E16/ E17
E13
E14
10
EN
PROBLEM
Banknote length error
Magnetic ink properties error
Infrared properties error
Banknote thickness error/Double note error
Slanted/diagonal note (note not inserted correctly)
Abnormal banknote retreat
Infrared image defective
Banknote without magnetic ink
Banknote magnetism exceeds magnetism limit

Publicité

loading