Télécharger Imprimer la page

Kärcher K 3.150 Notice Originale page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Operation
Description of the Appliance
Illustrations on Page 2
1 High pressure connection
2 Appliance switch "0/OFF"/ „I/ON"
3 Storage for mains connection cable
4 Transport handle
5 Storage for washing brush
6 Storage for spray lance
7 Storage for trigger gun
8 Detergent Tank
9 Connection for water supply with filter
10 Mains cable with mains plug
11 Bearing wheel
12 Coupling element for water connection
13 Trigger gun
14 Lock trigger gun
15 Key to detach the high pressure hose
from the trigger gun
16 High pressure hose
17 Washing brush
18 Spray lance with Dirtblaster
19 Spray lance with pressure regulation
(Vario Power)
Water supply
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.
 Use a fibre-reinforced water hose (not
included) with a standard coupling.
(Minimum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
14
 Screw the coupling element to the wa-
ter connection on the appliance.
 Push the water supply hose onto the
coupling unit, then connect it to the wa-
ter supply.
Drawing in water from open reservoirs
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
4.440-238) to draw in surface water, e.g.
from water butts or ponds (see specifica-
tions for max. suction height).
 Fill the KÄRCHER suction hose with
backflow valve with water, screw to wa-
ter supply and hang into the water butt.
 Appliance ventilation: Switch the appli-
ance on with the high-pressure hose
detached and operate (max. 2 minutes)
until the water exits the high-pressure
connection without bubbles. Switch off
appliance and reconnect high-pressure
hose.
Before Startup
Mount loose parts delivered with appliance
prior to start-up.
Illustrations on Page 2
Illustration
 Insert the transport wheels and lock
them.
Illustration
 Insert the transport handle and screw in.
Illustration
 Push the high pressure hose into the
trigger gun until it locks audibly.
Note: Make sure the connection nipple
is aligned correctly.
 Check the secure connection by pulling
on the high pressure hose.
EN
– 6

Publicité

loading