Fault
Cause
No travel
The wind alarm is active.
command can
be issued via
the hand-held
The batteries in the hand-
transmitter
held transmitter are fl at.
Motor has no power sup-
ply or is overheated
The blind does
WIND threshold value is
not travel up
set incorrectly
when it is
windy.
The blind
The LIGHT threshold
doesn't
value is not exceeded.
travel down in
Wind alarm is active
response to
sunshine
Rain alarm is active
Roller shutter mode is not
supported by the receiver.
The transmitter is set to
MANUAL mode.
Poor radio connection
Light sensor is dirty
The device
Device is already pro-
cannot be
grammed
programmed to
Poor radio connection
recognize the
receiver
The blind
The twilight threshold
doesn't
value is set incorrectly.
travel down in
The twilight function is not
response to
supported by the receiver.
darkness
The blind
Device is improperly pro-
travels down
grammed
when it is
windy.
All LEDs fl ash
Wind sensor is wet; device
is defective
Repair
Please contact your dealer if you have any queries.
All manuals and user guides at all-guides.com
Remedy
Wait until the delay
time has elapsed (15
minutes).
Change battery
Check power supply
or allow motor to cool
down.
Adjust the WIND
threshold value.
Adjust the LIGHT
threshold value
Wait until the delay
time has elapsed (15
minutes).
Wait until the delay
time has elapsed (15
minutes).
Change the mode
Set the transmitter to
AUTOMATIC mode.
Change the position
of the device.
Clean light sensor
Delete the device and
re-program it
Change the position
of the device.
Adjust the twilight
threshold value.
Use a different
receiver.
Delete the device and
re-program it
Allow the wind sensor
to dry