Intended use
• The operator has no protection whatsoever from
interferences by other telecommunication installations and
local terminals (e.g. also from radio installations) that are
normally used on the same frequency range.
• The range of the radio signal is limited by statutory
regulations and the structural conditions.
• Only use radio receivers with equipment and units approved
by the manufacturer.
• Using a number of receivers may cause interference.
Therefore, maintain a minimum distance of 15 cm between
the receivers.
• Before installing the unit at the specifi ed position, check the
proper function of the device and the receiver.
Intended use
The device must only be used to control awnings, venetian
blinds and roller shutters.
Third-party devices should only be connected after
consultation with your specialised dealer.
Other use, or use beyond this is not considered to be use for
intended purpose.
Exclusion of liability
elero GmbH assumes no liability for personal injuries, property
damage and fi nancial losses which arise from modifi cations
to the device, improper use and a failure to observe the
instructions. Liability for material defects is excluded in such
cases.
Defi nition of terms
In these instructions, the term "device" is used to describe the
BiSens SWR-230V.
For "down" or "closed" (closing, moving down etc.), "Down" is
used; for "up" or "open" (opening, retraction etc.), "Up" is used
in accordance with the designation of the buttons.
Scope of supply
BiSens SWR-230V, 1 wall bracket, 3 dowels, 5 screws, 1 nut
Accessories
Corner or mast support: Item Number 242690202v
Technical data
Operating voltage
Temperature range
IP Code
Radio frequency
Standby consumption
Weight
Dimensions
For USA, Canada, Australia, and some South American
countries, the following values apply:
Radio frequency
2 | EN
All manuals and user guides at all-guides.com
230 V/50 Hz
-20 °C to +60 °C
IP 44
868 MHz frequency band
2 to 7 W (BiSens SWR-230V)
630 g
L 205 x W 125 x H 105 mm
915 MHz frequency band
© weinor GmbH & Co. KG
Electrical connection
WARNING!
Risk of injury due to electrocution!
 Connections must be performed by an
authorised specialist!
1. Switch off the mains voltage.
2. Connect the cables of the device according to colour:
blue = N
black = L
3. Switch on the mains voltage.
The green operating LED indicates readiness for operation.
NOTICE!
Caution - Very Hot! Risk of burns if touched!
The rain sensor is hot when operating!
 Do not touch the rain sensor!
Mounting
There are several options for mounting.
CAUTION!
Downwinds on the façade can lead to
destruction of the device!
The device is not able to detect these winds.
 Do not mount the device under a jutty.
Note
For correct wind measurement, mount the device at
the façade in a position that allows it to catch all wind
directions.
Note
After mounting, remove the red cover cap from the wind
sensor.
Wall bracket
The device can be fastened to the upper side of the roof or to
the façade using the tilting wall bracket.