After a delay of 15 to 17 minutes, the blind will travel up.
The yellow light LED fl ashes during the delay time.
Use the HAND/AUTO switching function at the programmed
hand-held/wall transmitter to enable or disable the light
function.
Checking the light function (test mode)
Requirement
The blind is raised.
In the test mode the delay times are shortened from minutes
to seconds. In this way, the travel movements of the system
can be tested when the set threshold value is exceeded or
undercut.
1. Press and hold the UP button for at least 3 seconds until
the green operating LED fl ashes.
WARNING!
Risk of injury by downwards travel of awning,
roller shutter, or venetian blind!
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the
system.
2. Shine a torch on the light sensor.
A) The set light value is
reached or exceeded.
B) Less light. The set
light value is now un-
dercut.
You can repeat the operation as often as you want within 5
minutes.
Wind function
The wind speed is measured by the integrated wind sensor
and compared to the threshold value.
The wind signal is an emergency signal, hence the wind
function is always active.
Requirement
The blind is retraced.
The measured wind value exceeds the set threshold value;
the wind signal is triggered.
All manuals and user guides at all-guides.com
The yellow light LED shines. The
blind travels down immediately.
The yellow light LED fl ashes and
goes out after 15 seconds. The
blind travels up after 15 seconds.
© weinor GmbH & Co. KG
Blocked for
15 to 17 min.
The blind moves up and remains raised for a minimum of 15
to 17 minutes.
Red alarm LED shines.
The travel keys at the device are blocked.
The red alarm LED fl ashes during the delay time.
As long as the system is blocked, it is not possible to move
the blind down via a hand-held transmitter.
The block will be cancelled after the actual wind value has
undercut the threshold for 15 to 17 minutes.
Checking the wind function (test mode)
Requirement
The blind is raised.
In the test mode the delay times are shortened from minutes
to seconds. In this way, the travel movements of the system
can be tested when the set threshold value
is exceeded or undercut.
1. Press and hold the UP button for at least 3 seconds until
the green operating LED fl ashes.
WARNING!
Risk of injury by downwards travel of awning,
roller shutter, or venetian blind!
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the
system.
2. Use the hand-held transmitter to bring the blind to the
centre position.
3. Blow on the wind sensor.
A) The set wind value is
reached or exceeded.
B) Blow with less force.
The set wind value is now
undercut.
You can repeat the operation as often as you want within 5
minutes.
Programming the device
Red alarm LED shines. The
blind travels up immediately.
The red alarm LED fl ashes for
15 seconds.
EN | 5