Mast support
As an alternative, mount the device to a mast of 27 mm
diameter.
Corner or mast support
Use the corner or mast support to attach the device to the
corner of the façade or to the mast.
Setting the mode (awning, protection
against prying eyes, roller shutter)
The device can be operated in three different modes.
You can select the modes as follows:
1. Turn the wind potentiometer to Function.
2. Keep the UP and DOWN buttons pressed for at least 3
seconds. Press the two buttons until the device is in the
desired mode.
The fl ashing alarm LED indicates the mode of the device:
• Red alarm LED fl ashes once Awning mode
• Red alarm LED fl ashes twice Protection against prying
eyes mode
• Red alarm LED fl ashes 3x Roller shutter mode
The set mode is displayed at each radio transmission by the
fl ashing of the operating LED (LED fl ashing signal 1x per
minute).
Turn the rotary potentiometer from Function back to a value
selected by you.
The awning mode is set as standard in the delivery condition.
OEM versions may also be set to a different mode.
Note
Wind commands are executed in every mode.
The wind interlock is active for 15 to 17 minutes.
Setting the mode (awning, protection against prying eyes, roller shutter)
All manuals and user guides at all-guides.com
Awning mode
Requirement
Twilight function is switched off. (Twilight potentiometer is on
Off)
The awning will be retracted automatically when the current
sensor measured value changes from 1 to 0 (late in the
evening) or when the current light sensor measured value
changes from 0 to 1 (early in the morning).
Protection against prying eyes mode
Requirement
The light threshold value must be set to 2 or higher.
To keep the blind closed even in the evening, close the blind
manually using a weinor BiConnect hand-held transmitter.
The current transitions of the light sensor measured values
from 1 to 0 (late in the evening) or from 0 to 1 (early in the
morning) will be ignored.
The blind will remain closed throughout the night. The
travel commands such as tilting position (venetian blind)
or ventilation position (roller shutter) will be executed
automatically the next day.
Roller shutter mode
Requirement
The light threshold value must be set to 2 or higher.
Note
If the roller shutter is driven manually by a timer or the twilight
function to the lower end position, the light function (driving
according to set light value) will be switched off.
The current transitions of the light sensor measured values
from 1 to 0 (late in the evening) or from 0 to 1 (early in the
morning) will be ignored.
You can switch on the light function again in several different
ways:
• by means of a manual UP travel command to the upper end
• by means of an automatic timer command to the upper end
• by using the hand-held transmitter to switch from
Programming the device
Requirement
The end positions of the drive have been set. One transmitter
has been programmed.
1. Move the blind to the centre position.
2. Press and hold the UP/DOWN and P buttons on the hand-
3. Keep the STOP/P button pressed for 3 seconds until the
4. The blind moves up and down for 2 minutes.
© weinor GmbH & Co. KG
Support for the roller shutter mode is dependent on the
software version of the receiver.
position
position
AUTOMATIC mode to MANUAL mode and back to
AUTOMATIC mode.
held/wall transmitter simultaneously for at least 3 seconds.
green operating LED fl ashes fast. When the device is in
programming mode, the operative LED fl ashes fast each
time you press a button.
EN | 3