Programming the device
5. Press the UP button at the device immediately after the
start of upward travel. The drive will stop briefl y.
6. Press the DOWN button at the device immediately after the
start of downward travel. The drive will stop.
You have successfully programmed the device.
Symbols at the device
Alarm LED (red)
Light LED (yellow)
Operating LED (green)
Wind
Rain
Twilight
DOWN button
UP button
STOP /P button
Setting the threshold values
There are rotary potentiometers at the underside of the
device. You can set the threshold values in steps using the
rotary potentiometers.
OFF
Level 1
Light
Settings 2
to 14
Level 7
Level 15
Level 1
Settings 2
to 10
Wind
Level 4
Level 11
OFF
Level 1
Rain
Settings 3
to 14
Level 15
Level 2
OFF
Level 1
Twilight
Settings 2
to 13
Level 14
Note
The factory settings for OEM devices may differ from the
above.
4 | EN
All manuals and user guides at all-guides.com
/ P
The light function is switched off
Travel down at a low light level
Intermediate levels
Factory setting
Travel down at a high light level
Travel up at low wind speed
Intermediate levels
Factory setting
Travel up at high wind speeds
The rain function is switched off
Travel up at a low rain level
Intermediate levels
Travel up at a high rain level
Factory setting (BiSens SWR-230V)
The twilight function is switched off
Factory setting
Travel down at darkness
Intermediate levels
Travel down at start of twilight
© weinor GmbH & Co. KG
LED fl ash signals
Light LED (yellow)
Light value reached or exceeded, or twilight
shines
value reached or undercut
Light LED (yellow)
Flashes for the duration of the delay time:
fl ashes constantly
light value undercut
Alarm LED (red)
Measured wind value or rain value reached
shines
or exceeded
Alarm LED (red)
Delay time. Wind value or rain value under-
fl ashes constantly
cut
Operating LED
Device transmits in awning mode
(green) goes out
once
Operating LED
Device transmits in protection against prying
(green) goes out
eyes mode
twice
Operating LED
Device transmits in roller shutter mode
(green) goes out 3x
All LEDs fl ash
A sensor is defective or wet
Light function
The light intensity is measured by the integrated light sensor
and compared to the threshold value.
Requirement
The blind is raised.
min.
5 - 7 min.
The sun shines on the sensor for no less than 5 to 7 minutes.
The measured light value reaches or exceeds the set
threshold value.
The yellow light LED lights up.
After a short delay (5 to 7 minutes), the blind will travel down.
The weather situation is changing.
The measured light value falls below the set threshold value.