Télécharger Imprimer la page

GRAU XT-A Mode D'emploi page 11

Publicité

Les langues disponibles

Les langues disponibles

MODE 1
Individual Office or Open Plan Office (set for Individual office at delivery)
To use this function, the movement sensor must be active (Mode 2 ON)!
Individual office (Mode 1 OFF): After completion of after-glow period (factory setting 15 mins) the luminaire
switches itself off. The afterglow is the period between the last movement detected and the luminaire
switching itself off.
Set Individual Office with remote control:
0000
1
Open Plan Office (Mode 1 ON): After completion of after-glow period (factory setting 15 mins) the lumi-
naire dims itself to 20% lighting level for 2 hours then turns itself off. This ensures a basic brightness and
thus orientation in a space. Recommended for open-plan offices without lightdim connect (swarm function).
Set for open plan office with remote control:
0000
1
MODE 2
MOVEMENT SENSOR (activated at delivery)
Movement Sensor active (Mode 2 ON): The luminaire turns itself on/off depending on movement.
Activate Movement Sensor with remote control:
0000
2
The setting of the afterglow, see Afterglow
Movement Sensor deactivated (Mode 2 OFF): The luminaire must be manually switched on and off via the
switch.
Deactivate Movement Sensor with remote control:
0000
2
MODE 3
Constant Light Regulator (activated at delivery)
Constant Light Regulator active (Mode 3 ON): The luminaire dims itself depending on the ambient light level
to the Stored Light Value (see Mode 5)
Activate Constant Light Regulator with remote control:
0000
3
Constant Light Regulator inactive (Mode 3 OFF): The luminaire can be dimmed only.
Deactivate Constant Light Regulator with remote control:
0000
3
MODE 4
AC power interruption (Auto ON activated at delivery)
Auto ON (Mode 4 ON): Following an interruption of the mains voltage, the luminaire turns itself on, regard-
less of whether the luminaire was previously switched on or off. If no presence is detected by the movement
sensor, the luminaire turns itself off again after the Afterglow Period.
AC power interruption Auto ON:
0000
4
4

Publicité

loading