3.1. Prior to Installation
Prior to installing the heater, read all the instructions
for installation (figure 7), as well as checking the fol-
lowing points:
The heater volume should be suitable for the
sauna room volume. Table 2 shows the mini-
mum and maximum volumes for each heater
output. A precondition for the given values is
that the sauna room is well heatinsulated.
Walls and ceiling are covered with wood panel.
Check that supply voltage and amperages are
available for the heater.
The breakers and the connection cables con-
form with valid regulations and their dimen-
sions are in accordance with table 3.
The location is suitable for the heater ( 3.2.).
3.7. Resetting the Overheat Protector
Figure 5.
Minimum safety distances and sauna controls.
Heater
Output
kW
HPCS6U1HB
6,0
HPCS7U1HB
6,8
HPCS8U1HB
8,0
HPCS9U1HB
9,0
Table 2.
Installation details of the heater
3. INSTRUCTIONS FOR INSTALLATION
C
A
A
min.
2,8''/70mm
SEAL TIGHT CONDUIT
90°C WIRE
Dimensions
Width/Depth/
Weight
Height
inch
mm
lb/kg
14/13/40
37,5 17
360/340/1010
14/13/40
37,5 17
360/340/1010
14/13/40
37,5 17
360/340/1010
14/13/40
37,5 17
360/340/1010
EN
3.2. Place and Safety Distances
The minimum safety distances are described in
figure 4 and 5.
It is absolutely necessary to install the heater
according to these values. Neglecting them
causes a risk of fire. ( 3.6.)
Hot pieces of stone can damage floor coverings
and cause a risk of fire. The floor coverings of
the installation place should be heat-resistant.
3.3. Heater fence
It is necessary for safety and should be constructed
of softwood to match sauna interior. See figures 4
and 5 for clearances from sauna heater. Fence should
be attached to wall and should not be placed higher
than top of heater below rock line.
A
B
inch mm
inch mm inch mm
1,2
30
4
100 35
B
Stones
Sauna room
Cubic vol.
2.3.!
max.
min.
lb/kg
CuFt/m³
CuFt/m³
200 90
141 4
294 8
200 90
141 4
354 10
200 90
141 4
431 12
200 90
141 4
494 14
C
890
Floor Area
Height
max.
min
max
sqft
sqft
inch/mm
23
47
75 1900
23
57
75 1900
23
69
75 1900
23
79
75 1900
min.
9

Publicité

loading