Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TW-150 starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the TW-150 can be used without controller. You can do without a controller as the
TW-150 features a built-in microphone, which allows the projection to change colors according to the
automatic sound control.
Disconnect the TW-150 from the controller and set DIP-switch 10 to On.
Call up the internal program
In order to call up the internal program, set DIP-switches No. 9 and 10 to On.
DIP Switch:
Function:
9 + 10
Auto program
10
Auto sound control
10 + 1
Shutter open/white
10 + 2
Shutter open /cyan
10 + 2 + 1
Shutter open /yellow
10 + 3
Shutter open /violet
10 + 3 + 1
Shutter open /green
10 + 3 + 2
Shutter open /orange
10 + 3 + 2 + 1 Shutter open /blue
10 + 4
Shutter open /pink
10 + 4 + 1
Shutter open /rainbow with slow speed
Master/Slave-operation
Connect the master and slave-devices as desribed above and set the DIP-switches accordingly.
International
L
N
25/52
51785866_V_1_1.DOC