FRONT AIR
This menu allows the front ventilation motor speed to be set. Range: (comfort, auto).
If comfort mode is selected, the front air speed is reduced.
To guarantee e cient combustion, front air is excluded when the appliance is running at minimum power.
To set: OK > FRONT AIR >SET
EASY SETUP
The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change without altering
pellet quality. By using the EASY SETUP function, it is possible to change the calibration of the volumetric weight by increasing or decreasing
the preset values.
In the stove program, the available values range from "– 3" to "+ 3"; all stoves are calibrated during production with the optimal value which
is 0
If you notice an excessive deposit on the burning pot, access the EASY SETUP program and lower the value by one unit to "- 1"; then wait
until the next day and if there is no improvement, decrease again, to a maximum of "- 3". Instead, if it is necessary to increase the calibration
of the volumetric weight of the pellet, change the factory value from "0" to "+ 1, + 2, + 3" as required.
To set: OK > EASY SETUP
EXCESSIVE PELLET DEPOSIT IN BURN POT
-3
-2
SECOND
THIRD DECREASE
DECREASE
RANGE IF THE
RANGE IF
FIRST TWO ARE
THE FIRST IS
INSUFFICIENT
INSUFFICIENT
N.B.: If these adjustments do not solve the problem of pellet deposits in the burn pot, please contact your local service centre.
CHRONO
This function allows stove ignition and switch-o to be automatically programmed.
The factory setting for CHRONO is o .
The chrono allows the programming of 4 time slots per day, which can be used every day of the week. For each time slot, it is possible to
set ignition and switch-o times, speci c days of application, desired temperature and set power. Current day and time settings
are essential for the correct operation of the Chrono.
Recommendations
Before using the chrono function, it is necessary to set the current day and time. Therefore, check that the points in the sub-section
"DATE TIME" have been followed. To use the chrono function correctly, it must not only be programmed, but also enabled. The 4 time
slots can be overlapped using the ignition and switch-o time settings. In this way, it is possible to create a combination of time slots
with di erent temperatures and power levels, without changing the status of the stove.
N.B.: in the case of overlapping time slots, the stove will remain on until the last switch-o time.
62
NORMAL OPERATION
-1
FIRST DECREASE
OPTIMAL FACTORY
RANGE (TEST FOR
VALUE
1 DAY)
ENGLISH
MINIMUM PELLET DEPOSIT IN BURN POT
0
+1
FIRST INCREASE
RANGE
+2
+3
SECOND
THIRD INCREASE
INCREASE RANGE
RANGE IF THE
IF THE FIRST IS
FIRST TWO ARE
INSUFFICIENT
INSUFFICIENT