Télécharger Imprimer la page

Dal Zotto Inserto 700 Air Manuel Utilisateur page 61

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OPERATION AND LOGIC
IGNITION
Once the previously listed points have been checked, press key
for a ame for a period of 15 minutes. Once the control temperature has been reached, the
stove interrupts the ignition phase and switches to PREPARATION.
PREPARATION
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK
WORK
In the work phase, the stove operates at the POWER de ned by the user, heating the room until SET THERMOSTAT is achieved. See next
heading.
ADJUSTING SET THERMOSTAT
The ambient SET THERMOSTAT can be set using keys 2 and 3, from LOW TA 7 - 37 °C - HOT. If the value is between 7 - 37 °C, the stove checks
the ambient temperature by means of the radio control probe. Once the set temperature has been reached, the stove automatically reduces
the power, guaranteeing best comfort and reducing pellet consumption: this process is called "modulation".
LOW TA HOT
If the SET THERMOSTAT is "LOW TA" (set under the 7° threshold), temperature checking is entrusted to the additional thermostat contact,
thus bypassing the radio control temperature probe.
If the contact is open (ful lled), the stove works at minimum power.
If the contact is closed (request), the stove works at the set power.
If the setting is on "HOT" (set above 37°C), the stove only works at the set power, thus bypassing the external contact and the temperature
probe.
ADJUSTING SET POWER
The power has 5 operating levels, when key
Power 1 = minimum level - Power 5 = maximum level.
The change must be con rmed by pressing the key
AUTO BLOW
During the work phase, the stove cleans the burn pot at regular intervals with an "AUTO BLOW".
When this procedure starts, a message is displayed. During the "AUTO BLOW" procedure, the pellet feed slow down and the fumes motor
increases.
After cleaning, the stove resumes operation in normal conditions.
SWITCH OFF
Press the key
for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
OK
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the safety settings.
REIGNITION
The stove can only be re-ignited if the temperature of the exhaust fumes is lower than the preset threshold and the minimum safety time has
passed.
DO NOT USE ANY TYPE OF FLAMMABLE LIQUIDS FOR IGNITION!
DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE
FILLING PHASE!
IN THE EVENT OF CONTINUED FAILURE TO LIGHT, CONTACT AN AUTHORISED TECHNICIAN.
NO IGNITION
THE APPLIANCE MAY FAIL TO LIGHT BECAUSE THE AUGER IS EMPTY AND NOT ALWAYS ABLE TO LOAD THE BURN POT
FAST ENOUGH WITH THE PELLETS NEEDED FOR NORMAL IGNITION.
IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS OF OPERATION, CHECK THAT THE ROUTINE CLEANING
DESCRIBED IN THE STOVE HANDBOOK HAS BEEN CARRIED OUT CORRECTLY
for three seconds to ignite the stove. During ignition, the stove will check
OK
is pressed, the set power is displayed; it can be changed using keys
OK
.
OK
ENGLISH
or
.
OK
61

Publicité

loading