6 Installation
6.10.2
Raccorder les circuits électriques
Fig.72
Schéma de câblage et sections de câble recommandées
IDU
230 V~
Typ C
10 A
Backup
230 V~
Typ C
32 A
Typ B
DIF*
30 mA
Typ C
AWHP2R 4 MR : 20 A
AWHP2R 6 MR : 20 A
AWHP2R 8 MR : 20 A
AWHP2R 10 MR : 20 A
AWHP2R 12 MR : 32 A
AWHP2R 16 MR : 32 A
AWHP2R 12 TR : 16 A
AWHP2R 16 TR : 16 A
64
3 x 1,5 mm²
Tout
EHC
3kW / 230 V~
3-6kW / 230 V~
L 1
L 1
L 2
L 2
L 3
L 3
D 3
D 3
N
N
L 1
L 1
L 2
L 2
L 3
L 3
L1 L2 L3 D3 N
L1 L2 L3 D3 N
3 x 6 mm²
3 x 6 mm²
AWHP2R 4 MR : 3 x 4 mm²
AWHP2R 6 MR : 3 x 4 mm²
AWHP2R 8 MR : 3 x 4 mm²
AWHP2R 10 MR : 3 x 4 mm²
AWHP2R 12 MR : 3 x 6 mm²
AWHP2R 16 MR : 3 x 6 mm²
L
N
Laux
Naux
3-6kW / 400 V 3N~
L 1
L 1
L 2
L 2
L 3
L 3
D 3
D 3
N
N
L1 L2 L3 D3 N
5 x 2,5 mm²
AWHP2R 12 TR : 5 x 2,5 mm²
AWHP2R 16 TR : 5 x 2,5 mm²
PQE
2 x 0,35 mm²
< 30 m
D 3
D 3
N
N
400 V 3N~
230 V~
L1 L2 L3
MW-1002284-2
7802480 - v05 - 01122022
400 V 3N~
Typ C
16 A
BUS
P Q
E
3 x 0.5 mm²
shielded