MYCOMFORT LARGE
Key to symbols used in wiring diagrams
Vo
Extra-low speed
V1
Minimum speed
V2
Medium speed
V3
Maximum speed
L
Phase
PE
Ground
N
Neutral
RE
Heating element
EN
SW
Water sensor
SA
Air sensor
SU
Humidity Probe
BK
Black (Max. speed)
BU
Blue (Med. speed)
RD
Red (Extra low speed)
WH
White (common)
GY
Grey
BN
Brown (Min. speed)
GN
Green
YE
Yellow
MS
Flap microswitch
DI1
Digital 1 input
DI2
Digital 2 input
CI12
Digital input common
A-B-GND RS 485
F
Fuse (not supplied)
IL
Circuit breaker (not supplied)
CN
Terminal board
RHC
Heating/Cooling remote selecting switch
EXT
External auxiliary contact
KP
Circuit board to control 4 indoor units
IPM
Circuit board for UTN units
M
Fan motor
VHC
Solenoid valve –Cool/Heat.
VC
Solenoid valve - Cooling
VH
Solenoid valve - Heating
TSA
Automatic safety thermostat
TSM
Safety fuse
SC
Wiring box
.....
Electrical connections to be made by installer
FC66002638 - rev. 08
È severamente vietata la riproduzione anche parziale di questo manuale / All copying, even partial, of this manual is strictly forbidden
TECHNICAL DATA
ON-BOARD CONTROLLER INSTALLATION
The LCD controller can be installed directly (on both sides) on ESTRO, FLAT and 2x1
units using the controller kit provided, which contains:
-
Remote air temperature sensor (cable length 1.5 m)
-
LCD frame (to be added or replaced in case of flap)
-
Support for installation on the indoor unit
-
Reinforcement bracket (for Flat and 2x1 series)
-
Frame (for Estro series)
-
Sensor holder trap and clamp
NB: Prior to installation, carefully remove the protective film from the display; removal of
the film may cause some dark streaks to appear on the display but these will disappear
after a few seconds and are not signs of a controller defect.
FLAT
Installation on the support and fan coil unit
1. Remove the four screws concealed by the flap and take off the fan coil unit cabinet.
(Fig. 12).
Fig. 12 Removal of Flat cabinet
2. Open the controller after removing the screw of the cover; pass the cables through
the rear slot and wire them to the connectors as indicated in the diagram. Plug in
the connectors and close the controller again.
Fig. 13: Wiring cables of the controller
3. Pass the cables through the slot in the support and fasten the support and controller
together using the two screws provided. (Fig. 14 shows how the controller and
support are assembled together in the case of a controller mounted on the right
side of the fan coil unit; if the controller is mounted on the left side the support
must be turned by 180° compared to the drawing)
Fig. 14: Controller support fastening
4. Make the electrical connections according to the diagrams provided in this manual
(remove any connection cable for valve and heating element where these devices
are not present).
5. Once the electrical connections have been made, before completing installation
of the controller it is recommended to carry out the self-diagnosis procedure to
check whether all outputs are functioning correctly (fan at the different speeds
and valves where present). Refer to the relevant section in this manual.
6. Mount the controller-support assembly on the fan coil unit using the screws
provided.
Fig. 15 Fixing the support-Flat
7. Install the reinforcement bracket
Fig. 16 Reinforcement bracket
48