MYCOMFORT LARGE
-
System pipes: 2
-
Valve: 3 ways
-
Heating element: yes
-
Speeds: 4
-
Summer/winter switching logic: remote
EN
-
System pipes: 2
-
Valve: 3 ways
-
Heating element: yes
-
Speeds: 4
-
Summer/winter switching logic: air
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 3
-
Summer/winter switching logic: local
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 3
-
Summer/winter switching logic: remote
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 3
-
Summer/winter switching logic: air
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: local
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: remote
-
System pipes: 4
-
Valve: no
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: air
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 3
-
Summer/winter switching logic: local
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 3
FC66002638 - rev. 08
È severamente vietata la riproduzione anche parziale di questo manuale / All copying, even partial, of this manual is strictly forbidden
-
Summer/winter switching logic: remote
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 3
-
Summer/winter switching logic: air
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: local
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: remote
-
System pipes: 4
-
Valve: 2-3 ways
-
Heating element: no
-
Speeds: 4
-
Summer/winter switching logic: air
-
System pipes: 4
-
Valve: no
-
Heating element: yes
-
Speeds: 3
-
Summer/winter switching logic: local
-
System pipes: 4
-
Valve: no
-
Heating element: yes
-
Speeds: 4
-
Summer/winter switching logic: local
CONFIGURATION OF DIGITAL OUTPUTS (PARAMETERS
P09,P10,P11,P12)
P09, P11 = 0
The digital output is not governed by the controller; the contact is always open.
P09,P11 = 1
The contact status reflects the current operating mode (summer or winter) of the unit.
P09,P11 = 2
The contact status indicates the operation mode of the unit: cooling (summer) or
heating (winter).
P09,P11 = 3
The contact status indicates that the unit is in cooling mode.
P09,P11 = 4
The contact status indicates that the unit is in heating mode.
P09,P11 = 5
The contact status indicates if the control in ON or OFF
P09,P11 = 6
The contact status indicates if an alarm is triggered (serious or non-serious, see "Alarms")
36