Installer, please fill out the following information:
Customer:
Address:
Date of Installation:
Location of appliance:
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas:
CDVS600-1NA
CS600-1NA
When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specific recommendations from
the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft (305m).
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
CDVS600-1 - This appliance is not approved for closet or recessed installations. It is approved for bathroom,
bedroom and bedsitting room installations. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes. (Rear vent) Rear exit installations which termi-
nate horizontally and have no vertical vent runs must have the BTU input reduced to 21,000 BTU/hr by changing
the orifice (supplied).
CS600-1- This appliance is approved for bedroom and bed-sitting room installations.
Altitude (FT)
Max. Input (BTU/
35,000 (Top vent)
HR)
21, 000 (Rear vent only)
Max. Output (BTU/
HR)
Min. Inlet Gas
Supply Pressure
Max. Inlet Gas
Supply Pressure
Manifold Pressure
(Under Flow
Conditions)
Propane:
CDVS600-1A
NG
0-4,500
31,500 (Top vent)
21,000 (Rear vent only)
27,300
4.5" (11mb)
Water Column
7" (17mb)
Water Column
3.5" (9mb)
Water Column
standard checklist
CDVS600-1PA
CS600-1PA
1.0 general information
P
35, 000
24,570
27,300
11" (27mb)
4.5" (11mb)
Water Column
Water Column
13" (32mb) W
7" (17mb)
ater Column
Water Column
10" (25mb)
3.5" (9mb)
Water Column
Water Column
CS600-1A
NG
P
0-4500
31,500
24,570
11" (27mb)
Water Column
13" (32mb)
Water Column
10" (25mb)
Water Column
W415-4084 / A / 06.01.22
EN
5