operation
EN
9.3
flame characteristics
It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
9.4
restricting vertical vents - model CDVS600-1
Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must be
restricted using a restrictor vent kit. Refer to the "replacement parts" section of the owner's manual for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating a
more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
44
W415-4084 / A / 06.01.22
SIT ELECTRONIC IGNITION
3/8" - 1/2"
(9.5mm - 12.7mm)
ADD IMAGE
HERE
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
36.1
SIT MILLIVOLT
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
PSE LONG SENSOR
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple