3.0 installation preparation - model CDVS600-1
installation preparation - model CDVS600-1
EN
3.1
orifice replacement
REAR VENT TERMINATION:
Rear exit installations which terminate horizontally and have no verti-
cal vent runs must have the BTU input reduced to 21,000 BTU/hr by
changing the orifice (supplied).
In order to access the orifice, the log support secured by two screws,
must be removed.
Care should be taken not to damage the manifold gas pipe. When
removing the orifice, using a socket wrench, a back-up wrench must
be used on the manifold, located below the housing, to ensure that the
aluminum tubing does not twist or kink.
3.2
changing a top vent to a rear vent
Outer Top
Top Heat
7" (178mm)
7" (178mm)
4" (102mm)
4" (102mm)
22
W415-4084 / A / 06.01.22
Shield
Collar
Gasket
Collar
Gasket
In order to convert the venting configura-
tion from a top exit to a rear exit, remove
components as illustrated. When rein-
stalling in the alternate position: Check
gaskets for tears, replace if necessary to
ensure a proper seal.
7" (178mm) Gasket
4" (102mm)
Cover Plate
4" (102mm)
Gasket
Optional trivet required when converting
to rear exit.
7" (178mm)
Cover Plate