REAR VENT
4.2
appliance vent connection - model CDVS600-1
A.
Attach the adjustable pipe to the last section of rigid pipe. Secure with
#8 X 1/2"
screws and seal.
Self
Drilling
Install the inner fl ex pipe to the appliance. Secure with a minimum of
B.
Mill Pac
Screws
Sealant
three screws and fl at washers when installing 3"/5", 4"/7" or 5"/8"
venting, or six screws and fl at washers when installing 8"/10" or
8"/11" venting. Seal the joint and screw holes using Mill Pac sealant
1 1/2"
(W573-0007) (not supplied).
(38.1mm)
Overlap
Run a bead of high temperature red RTV silicone sealant (W573-
C.
0002) (not supplied) around the inside of the air intake collar. Pull the
adjustable pipe a minimum 2" (50.8mm) into the air intake collar.
note:
Always fi nish vent system installation with the appliance vent connection. Ensure that the sealant is not visible on the
exterior pipes once installation is completed. An optional decorative black band may be available with this appliance.
In the event that the venting must be disassembled, care must be taken to reseal the venting.
TOP VENT - FLEX
#8 X 1/2"
Self Drilling
Screws
1 1/4" (31.8mm)
Overlap
Mill-Pac Sealant
Red RTV
Silicone
installation
TOP VENT - RIGID/FLEX
#8 X 1/2"
Self Drilling
INSERT
Screws
2" (50.8mm)
IMAGE HERE
Overlap
Mill-Pac
Sealant
19.2
W415-4084 / A / 06.01.22
EN
#8 X 1
Self Dr
Screw