Programming
FUNCTION
AWNING/VENETIAN BLIND, PROGRAMME MODE, RUNNING TIME
(Curtain/canopy selection, programme mode, running time of the
awning/venetian blind)
1. Press the MENU button.
2. To select the FUNCTION menu, press the + button until
FUNCTION appears.
3. Confirm by pressing OK. AWNING/VENETIAN BLIND will
appear.
4. You can select either awning or venetian blind using the
+/- button.
5. Confirm by pressing OK. PROGRAMME MODE will appear.
6. You can activate the PROGRAMME MODE by using the
+/- button. The sensor is programmed by pressing the PROG
button. The device returns to operating mode after successful
programming.
7. Confirm by pressing OK. RUNNING TIME will appear.
8. You can set the required running time using the +/- button
(default setting: 120 seconds).
9. Confirm by pressing OK.
10. The RUNNING TIME function has now been set.
Please read on for further programming options using the
FUNCTION menu.
73