Instruction for installation
and use
Application
Smaller entrance halls, cashier's or check-
out counters and other spaces where a long
and narrow heating/air flow is required.
Thermozone is designed to be mounted above
smaller openings and lobbies. It provides a
concentrated vertical airflow.
MOUNTING
As a general rule the Thermozone should be
mounted as close to the opening's top as
possible in order to ensure the best function.
•
Measure out, mark and cut out holes for
the brackets, c-c 600 mm. Mount the
brackets
onto the wall upwards or downwards with
consideration to the minimum measures
and restrictions (A).
Slide the Thermozone sideways into the
grooves in the brackets. Tighten the
screws! (B)
•
When mounting on a pendulum the
brackets must be turned around as in fig.
(C) to ensure the Thermozone hangs
straight down.
•
Beam, balk and girder mounting requires
that the threaded holes on the air
curtain's top be used for mounting. (When
being mounted in a false ceiling make
sure that the Thermozone receives
enough intake air supply and that no
ventilation can interfere with the air
curtain's function).
•
NB! Do not mount the Thermozone so
that in- or out airflow is hindered!
Electric installation
The Thermozone is delivered with flexible
cord and grounded plug. A permanent
installation (without plug) should be preceded
by an all-pole switch with at least 3 mm
breaking gap.
NB! The wall socket for AD 103 must be
protected by a 16 amps fuse.
6
All manuals and user guides at all-guides.com
GB
Function
The thermostat is adjusted on an ascending
scale with 20°C indicated.
Overheating
If the airflow is hindered, the built-in tem-
perature limitier will be triggered and the
Thermozone cease to function. A qualified
electrician must be contacted to rectify the
fault and reset the limiter.
NB! The appliance must not be covered
either with clothes or similar material, since
overheating of the appliance can be a fire
hazard!
Ground contact
If the appliance is protected by an RCCB and
this is triggered when connecting the
appliance this might be due to dampness in
the heating rods. This should not be conside-
red a fault and is easily corrected by
connecting the air curtain to a wall-outlet
without RCCB so the heating rods can dry. It
may take anywhere from one hour to a
couple of days. To prevent this it is best to
operate the unit for short periods during a
long storage.
TECHNICAL DATA, see page 12.
off
half fan, half power
(AD 102 only: half fan, full power)
full fan, half power
full fan, full power