Malfunction causes
Error code
Ambient light is too high
E10
UV sensitivity light is too high
The plastic button is broken
E11
The fake bill reflecting fluorescence is being
EE1
checked out by UV - USA Setting Only
The fake bill without magnet is being checked
EE2
out by MG - USA Setting Only
Currency other than Canadian detected
EE3
The half bill is being checked out
EE4
The left (right) counting sensor is dirty or broken
The fake bill with different located magnet is
EE6
being checked out by MG - USA Setting Only
the bill width size is over 5mm larger than
EE8
the real USD bill size - USA Setting Only
Two bills are counted as one / inaccurate counting Fasten the adjustable screw clockwise
EE9
All manuals and user guides at all-guides.com
9
RBC-2200-CA
Solutions
Lower the ambient light
Lower the UV light
Replace button
Take out the first bill (fake bill) in the stacker then press
[reset] to continue counting and detecting
Take out the first bill (fake bill) in the stacker then press
[reset] to continue counting and detecting
Remove Foreign currency in the stacker, then press RESET to
continue counting and detecting
Take out the half bill in the stacker, then press [reset] to
continue counting &detecting
Replace counting sensor
Take out the first bill (fake bill) in the stacker then press
[reset] to continue counting and detecting
Take out the first bill (fake bill) in the stacker and press
[reset] to continue counting and detecting