6.9
Electrical diagram
~
Safety
thermostat
Limit
thermostat
 Do not invert the neutral with the phase in the
electrical supply line.
 Check that the electrical supply of the burner
corresponds to that shown on the identifica-
WARNING
tion label and in this manual.
 The section of the conductors must be at
least 1 mm
local standards and legislation).
Test the burner by checking the shut-down of the
burner by opening the thermostats and the lockout
by darkening the flame sensor.
WARNING
20119857
Start-up, calibration and operation of the burner
50Hz - 230V
PE
L
N
Main switch
T6A
Remote lock-out signal
(230V - 0.5A max.)
Burner-earth
Resistance
White
D4645
2
. (Unless requested otherwise by
CONTROL BOX
535RSE/LD
Blue
White
Black
CAUTION
16
GB
Ignition
electrodes
Flame sensor
Oil valve
Motor
Capacitor
If the cover is still on, remove it and proceed with
the electric wiring following the wiring diagrams.
Fig. 15