Télécharger Imprimer la page

Sime FUEL 25 ErP Instructions Pour Installation, Utilisation Et Entretien page 36

Publicité

Les langues disponibles

Les langues disponibles

6.5
Electrodes setting
These dimensions Fig. 13 must be respected.
WARNING
6.6
Fuel heating
In order to obtain smooth starting and operation across its output
range the burner is fitted with an electric resistance, which heats
up the light oil in the nozzle line.
This resistance is energized when the thermostat calls for heat
and after a delay of approximately two minutes depending on
room temperature, the motor will start.
6.7
Air damper adjustment
The settings indicated in the schedule are purely indicative. Each
installation however, has its own unpredictable working condi-
tions: actual nozzle output; positive or negative pressure in the
combustion-chamber, the need of excess air, etc.
All these conditions may require a different air-damper setting.
20119857
Start-up, calibration and operation of the burner
4 ±
0.3 mm
D5230
Before removing or assembling the nozzle, loosen the screw (A,
see Fig. 13) and move the electrodes ahead.
A
2 - 2.5 mm
The resistance remains energised during working and cuts out
when burner shuts-down.
14
GB
Fig. 13

Publicité

loading

Ce manuel est également adapté pour:

Fuel 35 erp20119424201194262013143920131442