MMA WELDING (ELECTRODE)
• Apply the usual welding rules.
• Leave the machine connected to the power supply after welding in order to let it cool down.
• Thermal protection : in case of over-heating the thermal protection light turns on. The cooling time is about 2 to 5 min
according to external temperature.
Advice :
• Respect welding polarities and currents indicated on the electrode packaging.
• Remove the electrode from the electrode holder when you do not use it.
• Leave the ventilation grill free to allow in/out air circulation.
TIG WELDING WITH INERT GAS
These machines can weld DC TIG with scratch start (100/130/180)
TROUBLESHOOTING
Symptoms
The 2 indicators are on, the machine does not
deliver any current.
The green indicator is on, but the machine
does not weld.
The product is under voltage, you are feeling
tingling when touching the machine's body.
The machine welds poorly.
PROGYS 180A
Causes
The thermal protection has switched on.
Fault with earth clamp/cable connection.
The earth contact is faulty.
Polarity error (+/-).
Remedies
Wait for the end of the cooling cycle.
Check the connections
Check the plug and the earth of your installa-
tion.
Check the polarity (+/-) recommended on the
electrode box.