DELAY TIME
Delay time refers to the time the cartridge filter is set to change from the
dark to bright state after welding stops. The delay can be adjusted up to a
0.9 second delay.
A short delay is suitable for spot or short welds. This allows you to track
the progress of the weld. A long delay is better suited for heavy welding
when there is an afterglow.
1.
Select the weld mode, then press the DELAY button until the delay
icon (P) flashes.
2.
Each press of the DELAY button will add a bar to the delay time. Each
bar increases the delay by 0.2 seconds starting from 0.1 to 0.9
seconds.
SENSITIVITY
Sensitivity is the degree the lens darkens based on the arc brightness and the
amount of light in the work area. This setting can be manually adjusted when
in welding mode.
1.
Select the weld mode, then press the SENS. button until the
sensitivity icon (O) flashes.
2.
Each press of the SENS. button will add a bar to the sensitivity. Each
bar increases the sensitivity by 0.2 seconds starting from 0.1 to 0.9
seconds.
Low Setting (0.1)
Medium Setting (0.5) Suitable for most indoors and outdoors
High Setting (0.9)
CUT MODE
WARNING! Do not use these goggles if the cutting task requires a
DIN shade higher than Shade 9. A bright cutting arc can cause
eye or retina damage if the Shade protection is inadequate.
8
TRUBLU LoPro Welding Mask Kit
Suitable for high amperage welding and
welding in areas with high levels of natural
sunlight.
welding.
Suitable for low amperage welding and welding
in areas with low light conditions, especially for
low amperage argon-arc welding.