Troubleshooting (cont.)
Symptoms
4.
Steam is coming out of
the steam head and the
control is shut off.
1230488-2-B
Probable Causes
B. The water supply is incorrectly
connected to the steam
generator.
A. Elevations over 6000' (1829 m)
above sea level can cause water
to boil at lower temperatures.
16
Recommended Action
A2. Partially open the water supply
shut-off valve.
A3. Allow the water to gradually fill
the steam generator tank (may take
several minutes). If the water
continues to flow from the steam
head, repeat A1 above.
A4. Fully open the water supply
shut-off valve.
A5. On models with power clean
option only: If water continues to
flow from the steam head, run the
power clean cycle.
A6. If water continues to flow from the
steam head, contact the Customer
Care Center using the information
on the back of this guide.
B. Review this manual, and if
necessary reconnect the water
supply to the proper location.
A. At elevations over 6000' (1829 m)
above sea level contact Kohler Co.
Customer Care Center for
instructions on disconnecting the
fast start coil.