Télécharger Imprimer la page

EuroLite TB-3 DMX-Roller Mode D'emploi page 18

Publicité

Les langues disponibles

Les langues disponibles

10
11
12
Blackout
(10) DMX-Out socket
(11) DMX-In socket
(12) Blackout-socket
(13) Microphone
(14) Sensitivity-control
(15) Fuseholder
(16) Power supply
(17) DIP-switches
INSTALLATION
Installing/Replacing the lamp
For the installation, you need one EFR 15 V/150 W GZ-6,35 lamp.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
All manuals and user guides at all-guides.com
LIGHTING CONTROL
PROTOCOL DMX-512
DMX Out
XLR occupation:
1: Ground
2: Signal (–)
3: Signal (+)
DMX In
For setting the DMX
starting address see
projector head.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
18
Microphone
Sensitivity
Fuse: T 2 A, 250 V
Power supply:
230 V AC, 50 Hz ~
17
13
14
15
16

Publicité

loading