Vibration
The vibration total value (tri-axial vector sum) determined
according to EN60745:
Model BUC121
Work mode: cutting wood
Vibration emission (a
Uncertainty (K): 1.5 m/s
Model BUC122
Work mode: cutting wood
Vibration emission (a
Uncertainty (K): 1.5 m/s
• The declared vibration emission value has been mea-
sured in accordance with the standard test method and
may be used for comparing one tool with another.
• The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
• The vibration emission during actual use of the power
tool can differ from the declared emission value
depending on the ways in which the tool is used.
• Be sure to identify safety measures to protect the oper-
ator that are based on an estimation of exposure in the
actual conditions of use (taking account of all parts of
the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to
the trigger time).
ENG900-1
2
): 4.2 m/s
h
2
2
): 4.3 m/s
h
2
ENG901-1
For European countries only
EC Declaration of Conformity
We Makita Corporation as the responsible manufac-
turer declare that the following Makita machine(s):
Designation of Machine:
Cordless Chain Saw
Model No./ Type: BUC122
Specifications: see "SPECIFICATIONS" table.
are of series production and
Conforms to the following European Directives:
2000/14/EC, 2006/42/EC
And are manufactured in accordance with the following
standards or standardised documents:
EN ISO 11681-2
The EC-Type Examination Certificate No. 4811004.13002
The EC-Type Examination per 2006/42/EC was per-
formed by:
DEKRA Testing and Certification GmbH
Enderstraße 92b
01277 Dresden
Germany
Identification No. 2140
The technical documentation is kept by:
Makita International Europe Ltd.
Technical Department,
Michigan Drive, Tongwell,
Milton Keynes, Bucks MK15 8JD, England
The conformity assessment procedure required by Direc-
tive 2000/14/EC was in Accordance with annex V.
Measured Sound Power Level: 93.0 dB (A)
Guaranteed Sound Power Level: 95.0 dB (A)
5.11.2013
Tomoyasu Kato
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi, 446-8502, JAPAN
Director