Features & Controls
Touch Controls
Baffle Filter Clean Reminder
A set of baffle filters are fitted by the factory, these baffle filters are intended to filter
out residue from cooking. The filters need not be replaced on a regular basis but are
required to be kept clean. The BaffleFilter Clean reminder function in the microproces-
sor will automatically indicate by a flashing
cleaned after every 60 hours of use. Filters can be cleaned by hand with non-abrasive
soap or in a dishwasher. Heavily soiled filters should also be soaked in grease cutting
detergent prior to cleaning.
Baffle Filter Clean Indicator
When
flashes on the display, the baffle
F
filters needo be cleaned. This will occur
after every 60 hours of use.
Reset the filter clean reminder timer after
filters are cleaned and re-installed. With
hood off, press and hold
mately 5 seconds until
disappears
function is now reset and a new 60 hours
elapse cycle is initiated.
Clean Air Function
Clean Air is a feature that turns on the blower on low speed every 4 hours for 10 minutes
to remove stagnant air in the kitchen. The Clean Air function is disabled by default and
must be enabled by the user.
Clean Air Indicator
While Clean Air is active, the display will
alternate between
After 10 minutes of Clean Air operation, the
blower will power off and the 4 hour timer
will reset.
If the blower speed is changed while the
Clean Air Function is in use, the cycle will be
interrupted and the timer will reset after.
18
for approxi-
on display
F
. The filter clean reminder
,
,
,
.
A
1
A
1
when the baffle filters need to be
F
Clean Filters
display < F > flashes
To Reset
hold 5 sec.
display from < F > to < >
To Enable
hold 3 sec.
and
To Disable
hold 3 sec.
display from < A > to < >
and
Monsoon II Use, Care, and Installation Guide
M O N S O O N I I
F
F
display < A > flashes
A
A
P R O
I N S E R T