Service
With cleaning and maintenance on the machine, the unit
should be turned off .
Th e fi ne fi lte should be changed at least once per year.
Use only original spare parts. If the machine is used with
a microfi lter/HEPA fi lter, this should be changed every
300 running hours, Use breathing protection when chan-
ging the fi lter. Used fi lters should be sealed in a plastic
sack and disposed of properly.
Accessories
Description
Plastic sack, standard
Fine fi lter cellulose, with
integrated fi lter cover
Microfi lter
Fine fi lter, polyester,
with integrated fi lter cover
Warranty
Th e warranty period for this machine is two years and co-
vers manufacturers faults. Th e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly. Normal wear is not covered by this warranty.
2010-08-23
Part no
4110
42026
42024
42025
DC 3800 TR Auto - 10
Th e DC 3800 TR Auto should be performance tested at
least once per year because it may be used with hazardous
materials. Worn parts must be replaced.
Never compromise the function of the DC 3800 TR, use
only original spare parts.
Other accessories — see Dustcontrol catalo-
gue.
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Part No 94118