Proceed as follows.
• Disconnect the power supply to the boiler.
• Remove the jumper (if present) at the ends of the
OpenTherm terminal on the boiler terminal block.
• Open the Comando Remoto by separating the
base B from the front panel C.
• Run the two wires, coming from the terminal block
or other Open Therm (OT) terminal present in boiler
A, through the hole in the base B to be mounted on
the wall.
• Connect the two wires to terminals D of the front
panel C.
• Secure base B to the wall using the plugs and screws
supplied with the accessory.
• Apply the front panel C on the base secured to the
wall, taking care not to press too hard.
• Power the boiler electrically, making sure that the
Comando Remoto switches on.
IMPORTANT
If fault E88 appears on the boiler display, there is a communication problem between the
boiler card and the control unit. Avoid placing cables near sources of heat, high voltage
and magnetic fields.