When running, the appliance will cool the cell until the currently set operating
temperature is reached. Once the set operating temperature is reached, the elec-
tronic control unit will turn off the cooling unit until the temperature detected by
the probe rises by about 4-5 degrees. When this happens, the control unit will
turn on the cooling unit to lower the temperature until it returns to the set oper-
ating temperature. This "on-off" mechanism is perfectly normal and is common
in all refrigeration equipment such as refrigerated bars, cabinets, display cases,
etc. Please note that the temperature shown on the control unit display refers to
the air temperature (very susceptible to temperature changes due to the opening
of the door) and not to the temperature at the core of the appliance, which is
much more constant over time.
Internal light
All models are equipped with internal light. Proceed as follow to turn on or off the light. Models
AKD100W, AKD200W, AKD300W, AKD400W:
Open the door;
Press the switch located in the upper part of the door stop frame.
Model AKD400WZ:
Press the L
IGHT
Error messages displayed on the control unit:
MESSAGE
Models AKD100W, AKD200W, AKD300W, AKD400W
Temperature probe defective or
P1
Model AKD400WZ
1H or 1L
2H or 2L
3H or 3L
HA or Lo
If one or more error codes are displayed, write them down, turn off the appliance then turn it back
on after 3-4 minutes. If one or more of the codes are again displayed, contact the dealer to request
technical support and inform them of the error codes.
Food storage
The following instructions should be followed in order for the appliance to perform at its best:
Put the food into the appliance after it has reached the desired temperature displayed on the
control unit. To avoid restricting air circulation, do not put too many products in the upper part
of the refrigerator;
Do not place hot foods inside the appliance (they must be previously cooled in a blast chiller)
or in unclosed containers. Always package and protect foods before putting them in the refrig-
erator;
Avoid opening and door frequently and for prolonged periods of time, and wait at least 30
seconds before re-opening the door.
TRANSLATION OF THE ITALIAN ORIGINAL INSTRUCTIONS
button (both with locked or unlocked keyboard).
ERROR DESCRIPTION
disconnected
Upper cell temperature probe
defective or disconnected
Lower cell temperature probe
defective or disconnected
Evaporator probe defective
Problems with the upper cell
temperature
EFFECT
The temperature is no longer be-
ing adjusted correctly
The upper cell temperature is no
longer being adjusted correctly
The lower cell temperature is no
longer being adjusted correctly
The evaporator does no longer
works correctly
The upper cell temperature
doesn't match the settings
SOLUTION
Contact the dealer
Contact the dealer
Contact the dealer
Contact the dealer
Contact the dealer
- 29 -