For information regarding bracket 5714/I please see technical
manual FT/SB2/07.
Art. 4714W/2I
3
5
4
6
1
10
Simplebus Intercom Bracket
Bracket for fixing the monitor - allows installation of the monitor on
the wall or by means of desk base Art. 4712W (see page 20), and
permits connection of the system cables.
Bracket Art. 4714W/2I can only be used on an intercom
network, i.e. connected to one of the outputs of an intercom
interface module Art. 4897.
The bracket is provided with terminals for connection of the floor
door call (see variant E), for connection of a call repetition device
(see SB2/T) and for use of pushbutton 1 of the monitor for various
uses (see variant A).
It is possible to insert up to 8 brackets Art. 4714W/2I with the same
user code in the same intercom network, i.e. connected to the
same Art. 4897.
The factory bracket Art. 4714W/2I can be used on Simplebus2
systems. It is compatible with Simplebus1 systems and to use it on
these some of the card settings must be changed. See "How to set
bracket Art. 4714W/2I for operation in Simplebus1 systems" on
page 30.
Installation of monitor Art. 4701W/A on wall
All manuals and user guides at all-guides.com
The label to be applied on the monitor is contained in bracket
Art. 4714W/2I, on which it is possible to indicate the functions
programmed for the pushbuttons.
2
7
8
Technical characteristics
9
Dimensions: 158x121x24.
8
1. monitor bracket connector.
2. terminals for connecting system:
3. CV5 bridge for closing video.
4. JP1 jumper for setting bracket as main or secondary (see
5. CN2 connector for programming by means of Art. 1251.
6. Dip switches for programming user code (see page 27).
7. CV2, CV1, CV7 bridges for additional monitor power supply by
8. CV3, CV4 bridges to free pushbutton 1.
9. CV6 bridge for selecting type of operation
10. JP2 jumper for selecting type of operation
MT SB2 03
0 +20V
terminals for connecting Art. 1212/B.
L L
for connecting bus line.
CFP CFP floor door call input.
P1 C1
pushbutton for various uses. To have a clean
NO contact, cut bridges CV3 and CV4.
S+ S-
terminals for call repetition device.
variant C and D).
means of Art. 1212/B (see diagram SB2V/010).
(Simplebus2 or Simplebus1).
(Simplebus2 or Simplebus1).
1
2
19
MT SB2 03