Fault code
Fault
F39
External probe fault
A41
Sensor positioning
A42
Heating sensor fault
Exchanger protection
F43
intervention.
F52
Heating sensor fault
A61
Controller ABM03 fault
No communication
A62
between electronic con-
troller and gas valve
A63
F64
Controller ABM03 fault
A65
F66
A23
A24
F20
F21
Card parameter fault
A26
F40
F47
5. TECHNICAL DATA AND CHARACTERISTICS
196
22
81
35
16
278
221
42
10
8
7
44
fig. 26 - General view
All manuals and user guides at all-guides.com
Possible cause
Cure
Probe damaged or wiring
Check the wiring or replace the sen-
shorted
sor
Probe disconnected after
Reconnect the external probe or dis-
activating the sliding
able the sliding temperature
temperature
Delivery sensor discon-
Check the correct positioning and
nected from the pipe
operation of the heating sensor
Sensor damaged
Replace the sensor
No system H
O circula-
2
Check the circulating pump
tion
Air in the system
Vent the system
Sensor damaged
Replace the sensor
Controller ABM03 inter-
Check the earth connection and
nal error
replace the controller if necessary.
Connect the controller to the gas
Controller not connected
valve
Valve damaged
Replace the valve
Controller ABM03 inter-
Check the earth connection and
nal error
replace the controller if necessary.
Wrong card parameter
Check the card parameter and mod-
setting
ify it if necessary
9
74
11
39
136
37
cod. 3541F842 - Rev. 00 - 11/2018
Table. 9 - Key of figures cap. 5
7 Gas inlet
8 Domestic hot water outlet
9 Cold water inlet
10 System delivery
11 System return
14 Safety valve
16 Fan
22 Burner
32 Heating circulating pump
35 Air separator
36 Automatic air vent
37 Cold water inlet filter
39 Flow regulator
42 DHW temperature probe
44 Gas valve
56 Expansion tank
72 Room thermostat (not supplied)
191
35
278
56
186
221
193
14
10
36
114
32
74 System filling cock
81 Ionisation/ignition electrode
114 Water pressure switch
136 Flow meter
138 External probe (optional)
139 Remote timer control (optional)
154 Condensate drain pipe
186 Return sensor
191 Fume temperature sensor
193 Trap
196 Condensate tray
221 Bypass cock
256
278 Double sensor (Safety + Heating)
340 Bypass pipe
A ON/OFF switch (configurable)