DC CIRCUIT PROTECTOR
A DC circuit protector has been provided to
protect the circuit from overloads. If an overload
occurs, the circuit protector will trip. The circuit
protector may be reset by pushing the button of
the protector.
Charging a large capacity battery or a totally
discharged battery may cause the DC breaker to
turn off. In these cases, a separate battery charger
unit connected to an AC power source is
recommended instead of the DC receptacle on
the generator.
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
Let the generator run at no-load for two minutes to stabilize
internal temperatures of the engine and generator.
2. Flip the engine switch to"OFF"(O) position.
3. Turn the fuel selector switch to "
(1:30 o'clock). The gasoline valve is close on this
position.
4. Fully close the LPG cylinder knob.
English
All manuals and user guides at all-guides.com
If a cover is used, do not install until unit has cooled.
NOTE: Disconnect the LPG cylinder from the
generator during transportation.
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
DO NOT stop engine by moving choke control
to "START" position.
Important: Always ensure that the
switch
is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
Low Oil Shutdown
If the engine oil drops below a preset level, an
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between the LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the LOW mark on dipstick:
LPG
" position
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
Do Not Overload Generator
Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
Page 25
WARNING
is in the "OFF" position when the engine
a low oil condition may still exist. DO NOT try
to restart the engine.
corrected.
Customer Service: 1-844-FIRMAN1
fuel selector