2. Check oil level.
3. Connect the regulator(A) to both LPG cylinder
and generator. Connect the power cord(B) to the
LPG regulator port. See "Connecting liquid Petroleum
Gas(LPG/Propane)
Cylinder
Use your fingers, slide the outer barrel back on
the LPG quick connect hose fitting. While the outer
barrel is in the back position, insert the LPG hose
(included) into the inlet and release the outer barrel.
The barrel will automatically return and lock the
hose in the inlet.
4. Fully open the LPG cylinder knob.
5. Turn the fuel selector switch to "LPG" position(1:30 o'clock).
6. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
English
All manuals and user guides at all-guides.com
" section on page 13, 14,15.
Page 20
7. Flip the engine switch to the "RUN"(l) position.
8. Push the battery power restore switch for about
3 seconds and then release.
9. Pull the choke lever out to the "CHOKE" position.
10. PULL TO-PRIME:
-
Pull the starter cord 1-2 times. Pull slowly until
resistance if felt and then pull rapidly.
11. Push the choke button to the "RUN" position.
12. PULL TO RUN:
-
-
Pull the starter cord slowly until resistance if felt
and pull rapidly to run the unit.
If the engine fails to start in 1-2 pulls with choke in the
"RUN" position, then move choke lever to "START"
position and repeat the "PULL-TO-PRIME" step.
Customer Service: 1-844-FIRMAN1