Features
• Assembled in USA
• 0-90 second field replaceable time delay retard
• Easy to read retard time delay adjustment knob
• Fits 1" to 2" CPVC plastic fittings
• Comes with all necessary paddles
• Two SPDT (form C) contacts
• Weatherproof
• Easy to read wire terminal designations
• 5 year warranty
• Installation must be performed by qualified personnel and in
accordance with all national and local codes and ordinances.
• Shock hazard. Disconnect power source before servicing. Serious
injury or death could result.
• Risk of explosion. Not for use in hazardous locations. Serious
injury or death could result.
Waterflow switches that are monitoring wet pipe sprinkler systems shall
not be used as the sole initiating switch to discharge AFFF, deluge,
or chemical suppression systems. Waterflow switches used for this
application may result in unintended discharges caused by surges,
trapped air, or short retard times.
Description
The Model VSR-SG is a vane type waterflow switch for use on wet
sprinkler systems using CPVC plastic fittings (manufactured by Tyco,
Nibco, Victaulic, Ipex, and Spears Manufacturing Company) that use 1",
1 ¼", 1 ½", or 2" pipe sizes. It is equipped with a union to accommodate
installation in confined spaces.
The VSR-SG contains two single pole, double throw, snap action
switches and an adjustable, instantly recycling pneumatic retard. The
switches are actuated when a flow of 10 GPM (38 LPM) or more
occurs downstream of the switch. The flow condition must exist for
a period of time necessary to overcome the selected retard period.
Enclosure
The VSR-SG switches and retard device are enclosed in a weather/
UV/flame resistant high impact composite plastic The cover is held
in place with two tamper resistant screws which require a special key
for removal. A field installable cover tamper switch is available as
an option which may be used to indicate unauthorized removal of the
cover. See bulletin number 5401103 for installation instructions of
this switch.
NOTICE
This document contains important information on the installation
and operation of the VSR. Please read all instructions carefully and
notify the building owner or their authorized representative before
any work is done on the fire sprinkler or fire alarm system. A copy
of this document is required by NFPA 72 to be maintained on site.
Potter Electric Signal Company, LLC
Vane Type Waterflow Alarm Switch w/Retard
Technical Specifications
Conduit
Entrances
Contact
Ratings
Enclosure
Environmental
Specifications
Flow
Sensitivity
Range for
Signal
Maximum
Surge
Service
Pressure
Service Use
Specifications subject to change without notice.
•
St. Louis, MO
•
•
5401205 - REV J
and Glue-In Union, For CPVC Pipe
Two knockouts provided for 1/2" conduit. Individual
switch compartments suitable for dissimilar voltages
Two sets of SPDT (Form C)
10.0 Amps at 125/250VAC
2.0 Amps at 30VDC Resistive
10 mAmps min. at 24VDC
Cover - Weather/UV/Flame Resistant High Impact
Composite
Base - Die-cast aluminum
NEMA 4/IP54 Rated Enclosure suitable for indoor or
outdoor use with factory installed gasket when used with
appropriate conduit fitting.
Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL
4-10 GPM (15-38 LPM) - UL
18 FPS (5.5 m/s)
Up to 175 PSI (12,07 BAR)
British Standard
Automatic Sprinkler
One or two family dwelling
Residential occupancy up to four stories
National Fire Alarm Code
Phone: 800-325-3936
10/21
VSR-SG
B59251
NFPA-13
NFPA-13D
NFPA-13R
NFPA-72
•
www.pottersignal.com
PAGE 1 OF 5