600
550
500
450
400
350
300
250
200
150
100
50
0
0
[EN] CIRCULATOR RESIDUAL HEAD
A - Residual head (x 100 mbar)
B - Capacity (l/h)
The residual head for CH system is shown in the
graph 1, depending on capacity.
CH pipes are to be dimensioned considering
residual head value available. Remember that
boiler properly operates if water circulation in heat
exchanger is sufficient.
To this purpose, the boiler is equipped with an
automatic bypass which regulates proper water
capacity to heat exchanger under any system
condition.
[PT] ALTURA TOTAL DE ELEVAÇÃO
RESIDUAL DA BOMBA CIRCULADORA
A - Altura total de elevação residual (x 100
mbar)
B - Caudal (l/h)
A altura total de elevação residual para a instala-
ção de aquecimento está representada, em função
do caudal, no gráfico 1. O dimensionamento dos
tubos da instalação de aquecimento tem de ser
efectuado considerando o valor da altura total
de elevação residual disponível. E' preciso ter
presente que a caldeira funciona correctamente
se no permutador do aquecimento houver uma
circulação de água suficiente. Para esta finalidade,
a caldeira é dotada de um by-pass automático
que provê, quaisquer que sejam as condições da
instalação, a regular um correcto caudal de água
no permutador do aquecimento.
100
200
300
400
[FR] PRÉVALENCE RÉSIDUELLE DU
CIRCULATEUR
A - Prévalence résiduelle (x 100 mbar)
B - Débit (l/h)
La prévalence résiduelle de l'installation de chauf-
fage est représentée en fonction du débit sur le
graphique 1.
Le dimensionnement des tuyauteries de l'instal-
lation de chauffage doit être effectué en tenant
compte de la valeur de la prévalence résiduelle
disponible. N'oubliez pas que la chaudière fon-
ctionne correctement si on a une circulation d'eau
suffisante dans l'échangeur du chauffage.
Dans ce but la chaudière est équipée d'un by-
pass automatique qui régularise le débit de l'eau
dans l'échangeur du chauffage en fonction des
conditions de l'installation.
[RO] CARACTERISTICA DE DEBIT A POMPEI
A - Cap rezidual (x 100 mbar)
B - Capacitate (l/h)
Presiunea reziduala pentru sistemul de incalzire
centrala este prezentat in diagrama 1, in functie
de capacitate. Tevile de incalzire centrala trebuie
dimensionate luand in considerare valoarea pre-
siunii reziduale disponibile. Centrala functioneaza
corect daca circulatia apei in schimbatorul de
caldura este suficienta. In acest scop, centrala
este echipata cu un dispozitiv automat de bypass,
care regleaza capacitatea apei la schimbatorul de
caldura, in orice conditii ale sistemului.
500
600
700
800
B
81
900
1000
1100
1200
[ES] ALTURA DE CARGA RESIDUAL DEL
CIRCULADOR
A - Carga hidrostática residual (x 100 mbar)
B - Caudal (l/h)
La carga hidrostática residual para la instalación
de calefacción está representada, en función de la
capacidad, por el gráfico 1. El dimensionamiento
de las tuberías de la instalación de calefacción se
tiene que efectuar teniendo presente el valor de
la altura de carga residual disponible. Hay que
considerar que la caldera funciona cor rectamente
si en el intercambiador de calefacción existe
una sufi c iente circulación de agua. Por eso la
caldera está dotada de un by-pass automático
que provee regular un correcto caudal de agua
en el intercambiador calefacción para cualquier
tipo de instalación.