FINAL SETUP
CLEANUP, VERIFY POWER
Remove any final packaging materials and protective film from all exterior areas.
Check the electrical requirements for the correct electrical supply and that the cooktop is properly
grounded.
Check power at the junction box wires using a voltmeter having a range of 0-250 VAC.
•
A 240 Volt supply should read 220 to 240 Volts between the black and red wires (Line to Line).
•
A 208 Volt supply should read 190 to 208 Volts between the black and red wires.
FUNCTIONAL TEST
The following test will confirm that the cooktop is working correctly.
1) Fill an induction-capable cookware piece with 1/2 - 1" [1.2-2.5 cm] of water and place it on one
of the cooking zones.
1) Switch the Control ON by touching the Power key(1).
2) Touch the zone [ON/OFF] key (13) for the
cook zone where the cookware is.
3) Touch the power slider for that zone and set
it to a level between 3 and 9.
4) Observe that the display responds to
the power setting, and observe that the
cookware begins to heat up.
5) Touch the ON/OFF key (13) for that zone to
turn it off.
6) Touch the Power key (1) to turn the
cooktop off.
Item
Function
1
Power key
2
Connectivity key
3
Connectivity indicator
4
Pause key
5
Pause / Recall indicator
6
Graphic indicating controlled zone
7
Power slider - minimum power
CRITERIA
If the controls respond as described and the cookware heats up, then the test is successful.
All manuals and user guides at all-guides.com
3
Figure 10. Cooktop controls
Item
8
9
10
11
12
13
13
12
min
ON
2
1
4 5
6
7
Function
Power slider - maximum power
Select Power Booster
Cooking zone level display
Power level indicator
Cooking zone indicator
Cooking zone ON/OFF
©2018 Hestan Commercial Corporation
11
10
8
9
11
EN