TFA_No. 35.1123_Anleit_01_23
19.01.2023
LOOK – Wireless weather station
• Check the transmission of 433 MHz signal from the transmitter to the display unit (transmission
range 30 m free field). Within ferro-concrete rooms (basements, superstructures), the received
signal is naturally weakened.
• If necessary choose another position for transmitter and/or basic station.
11. Care and maintenance
• Clean the instrument with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the batteries if the device will not be used for a long period of time.
• Keep the instrument in a dry place.
11.1 Battery replacement
• Replace the batteries when the display becomes weak.
• Please note:
When the batteries are changed, the contact between transmitter and receiver must be restored
– so always insert new batteries into both units or start a manual transmitter search.
12. Troubleshooting
Problems
Solution
➜ Ensure batteries polarities are correct
No indication
➜ Change the batteries
on the base station
➜ No transmitter installed
No transmitter reception
➜ Check the batteries of external transmitter
Display "---"
for channel 1/2/3
(do not use rechargeable batteries!)
➜ Restart the transmitter and the basic station as per the
manual
➜ Start manual search for the transmitter:
Press and hold the CHANNEL button on the base station
➜ Choose another place for the transmitter and/or the
base station
➜ Reduce the distance between the transmitter and the
base station
➜ Check if there is any source of interference.
➜ Change the batteries
Incorrect display
13. Waste disposal
This product and its packaging have been manufactured using high-grade materials and compo-
nents which can be recycled and reused. This reduces waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collection systems that
have been set up.
18
11:30 Uhr
Seite 10
LOOK – Wireless weather station
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries from the device
and dispose of them separately.
This product is labelled in accordance with the EU Waste Electrical and Electronic
Equipment Directive (WEEE).
This product must not be disposed of in ordinary household waste. As a consumer, you
are required to take end-of-life devices to a designated collection point for the disposal
of electrical and electronic equipment, in order to ensure environmentally-compatible
disposal. The return service is free of charge. Observe the current regulations in place!
Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordinary household
waste. They contain pollutants which, if improperly disposed of, can harm the environ-
ment and human health. As a consumer, you are required by law to take them to your
retail store or to an appropriate collection site depending on national or local regula-
tions in order to protect the environment. The return service is free of charge.
The symbols for the contained heavy metals are:
Cd=cadmium, Hg=mercury, Pb=lead.
14. Specifications
Base station:
Measuring range indoor
Temperature:
0 °C... +50 °C (+32°...+122 °F)
Humidity:
20 %rH ... 95 %rH
Power consumption:
2 x 1.5 V AAA (not included)
Dimensions:
85 x 24 (55) x 133 mm
Weight:
109 g (instrument only)
Outdoor transmitter:
Measuring range outdoor
Temperature:
-20°C... +60 °C (-4°...+140 °F)
Range:
max. 30 m (free field)
Transmission frequency:
433 MHz
Maximum
radio-frequency power:
< 10mW
Transmission time:
60 seconds
19