Settings for different parameters:
CV
Description
1
Adress
3
Acceleration delay
4
Braking delay
5
Maximum speed
*
17
Extended adress (upper part)
18
Extended adress (lower part)
Bit 0: Travel direction polarity reversal + lighting
29
Bit 1: Number of speed level 14/28
Bit 5: Adress size 7 bit / 14 bit
49
Pulse width for motor control
*
50
Rule variant
*
Bit 0: Motor polarity reversal
51
Bit 1: Only lightning
*
Bit 2: Track Polarity reversal
Other changes are not possible. The values set at
the factory have been selected to insure trouble-free
operation.
*
for the
DCC Value
Selectrix Value
1 - 99
0 - 127
0 - 127
1 - 7
CV 29 Bit 5 = 1
not necessary
CV 29 Bit 5 = 1
not necessary
0/1
not necessary
0 - 3
0 - 3
0/1
not necessary
The operating instructions for your central unit (example:
Central Control 2000) will give you exact procedures for
setting the different parameters. With many systems the
values set at the factory can be read in the programming
mode.
1 - 99
1 - 7
1 - 7
1 - 7
1 - 4
1 - 4
17