4. The pressure water piping of the machine can optionally
be connected to cold or 70°C warm water.
Make sure that water which is sucked in externally is clean.
Use a water inlet filter – art.no. 666560
The hose cross-section should be at least 1/2" = 12.7 mm
(free passage). Sieve No. 1 must always be clean.
5. Maximum intake height 2.5 m - see Technical Data
All manuals and user guides at all-guides.com
Pressure adjustment
By turning the hand wheel. Max. pressure cannot be altered.
Sucking in cleaning agents:
Place chemicals sieve No. 5 in tank with cleaning agent.
Open control nozzle No. 4, the injector can then suck in the
cleaning agent. The supply of chemical is automatically closed
when the control nozzle is closed. Leave cleaning agent to
take effect then rinse at high-pressure.
Open control nozzle for low
pressure!
Stopping:
1. Switch off device.
2. Turn off water supply.
3. Open pistol briefly until pressure relieved.
4. Lock pistol.
5. Unscrew water hose and HP hose.
6. Empty pump: switch on motor for approx. 20 seconds.
7. Unplug from mains.
8. In Winter: store pump in a frost-free room.
9. Clean water filter.
2 8
2 8
2 8
2 8
2 8
When the control nozzle is fully
open, 3-5 % admixture possible.
pH value neutral 7-9.
Pay attention to additive
manufacturer's instructions ! (e.g.
protective equipment)