8.0 fi nish framing - after appliance installation
There are various methods to ventilate the enclosure. Refer to "installation planning" section. Only one option is
illustrated (Installation Option 2 - front opening).
The appliance must be installed at this point of framing. Appliance is not shown to better illustrate framing.
single-sided fl ush
note:
Finish framing must be built after
appliance has been placed in its
fi nal position and venting
connected.
The LV series requires a minimum
enclosure height, as illustrated
(dimension L), measured from
the bottom of the appliance. For
temperature requirements, this
area must be left unobstructed.
Some venting confi gurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.
Installation Option 2 illustrated (appliance not shown)
minimum framing
Ref
LV38-1
K
E
53 13/16" (136.7cm)
F
J
L
Q*
(Q x R)*
* ONLY APPLICABLE TO OPTION 2 AND 3 - Opening must be centered in enclosure on appliance. Dimensions represent
fi nished sizes and where applicable should be adjusted to include fi nish material thickness.
fi nish framing - after appliance installation
Ceiling
L
J
LV50-2
39 15/16" (101.4cm)
20 1/8" (51.1cm)
65 13/16" (167.2cm)
Optional - Appliance does not need to be elevated above fl oor
73" (185.4cm)
2" min and 3" max
80 sq. in.
R
Q
K
E
F
Insulation
LV62
77 13/16" (197.6cm)
91" (231.1cm)
160 sq. in.
EN
Drywall
LV74
89 13/16" (228.1cm)
17
W415-2373 / B / 04.30.21