6.0 minimum clearance to combustible enclosures
minimum clearance to combustible enclosures
EN
single-sided
1" [25mm] minimum
all sides for sections
of vertical venting.
When passing through
a ceiling, use fi restop
spacer W500-0028
(not supplied)
0" to side standoffs
1/2" fi nishing fl ange
0" to bottom of the
appliance
Horizontal vent sections: A minimum clearance of 3" (76mm) on the top outside of the enclosure and 2"
(51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to com-
bustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6"(152mm) at the
top of the vent pipe.
Vertical vent sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is
required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a mini-
mum clearance of 1" (25mm) around the vent pipe.
minimum clearance
Ref
L
note:
The LV series requires a minimum inside enclosure height, as illustrated (dimension L) measured from the bot-
tom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting con-
fi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance
between vent pipes and combustibles.
14
W415-2373 / B / 04.30.21
L
LV38-1
LV50-2
73" (185.4cm)
6" [152mm] minimum
(inside enclosure)
3" [76mm] top (outside
of enclosure)
2" [51mm] sides /
bottom (outside of en-
closure)
When passing through
a wall, use fi restop
spacer assembly
W010-4178 (supplied)
0" to combustible
fi nishings such as brick
and stone. When using
non-combustible fi nish-
ings, only use fi restop
spacer (W615-0162)
included in the fi restop
assembly (W010-4178)
0" to back standoffs
fi restop spacer
(W615-0162)
LV62
LV74
91" (231.1cm)