4. Memorization of a position
This function allows you to adjust the tray to one of the 4 memorized posi-
tions.
If you turn on the control box for the first time, all 4 memorized positions are
already preset. To switch to a memorized position, follow the steps below:
a. Press the "UP" or "DOWN" button to set the tray to the desired height, this
height will be displayed on the screen.
b. Press and hold the "M" button for 3 seconds until the digits on the display
start flashing.
c. Press the memory location button 1 to memorize the tray position.
d. "P 1" will appear on the display, indicating the number of the position you
have memorized.
The other positions can be memorized in the same way.
The desk can be adjusted by holding down the "UP" or "DOWN" button until
the desired height is reached.
To program up to four presets: use the "UP" / "DOWN" buttons to find the de-
sired height, then press "M" followed by a number from 1 to 4.
PRECAUTIONS :
Once a preset button has been pressed, the desk will move to the pro-
grammed height.
5. Anti-collision system
The system has an anti-collision function, the sensitivity level of which is ad-
justable. In order to function properly, the control box must be properly at-
tached under the top, as described in STEP 8, and must only be connected to
the mains socket after it has been attached under the top.
a. Press the "M" and "2" buttons simultaneously for 5 seconds, "L3" will ap-
pear on the display, meaning that the sensitivity level can be adjusted.
b. Press the "UP" or "DOWN" button to adjust the sensitivity level. The sensi-
tivity level options are L0, L2, L3, L4. L0 indicates that the anti-collision func-
tion is disabled. L2 indicates the most sensitive level, L3 indicates a medium
sensitive level and L4 the least sensitive level.
c. Press "M" to save the setting.
19