IS NOT INSTALLED WITHIN THE PERIMETER OF BATH TUBS
OR SHOWERS. This means that it cannot be installed in the are-
as marked as VOLUME 1 in picture 1.
•
During function, place the heater in a safe position:
at least 1m far from inflammable objects or furnitures;
-
leaving not less than 1m of free space in front of the heater;
-
-
not located immediately below a socket-outlet.
•
Do not leave animals or children touch or play with the appliance.
Pay attention! The air outlet grille gets hot during operation (more
than 90°C)
•
WARNING: In order to avoid overheating, do not cover the
heater. Do not hang anything on the heater and do not cover it
while it's working. This is clearly written on the cover of the pro-
duct or shown by the symbol
•
Do not use the heater in rooms with explosive gas or while using
inflammable solvents or varnish or glues.
•
If the cordset is damaged and you have to change it, do not do
the job yourselves! Take the product to an after sales authorised
repair centre or to a person with similar skill and knowledge, in
order to avoid any risk of danger.
•
The appliance must be positioned so that the plug is always ac-
cessible.
•
Do not mount the product on walls made of synthetic material.
2. W
all Mounting
•
Only fix the heater in vertical position with the air outlet grid downward;
•
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth
connection.
•
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
•
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the
floor. The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum
gap between the contacts that allows complete disconnection according to excess voltage III category conditions.
•
To choose the best installation position please consider that the sensor is able to detect movements in the areas
shown in picture 2. Place the heater in the best position to detect people inside the room and to be clear from
any object that may interfere with the sensor's beam. Detection is more efficient when people move in front of
the product instead towards it.
•
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 3. Never
install the product so that the distance between the floor and the lower side of the product is less than 600 mm:
-
Drill three 6 mm diameter holes in the wall, as shown in picture 4
-
Insert the three wall plugs supplied with the product
15