1.
Introduction
The O
simulator 82 is used to test the functional integrity of the O
2
and the connecting cable. It simulates a METTER TOLEDO O
Each O
simulator 82 is tested by METTLER TOLEDO prior to delivery.
2
2.
Important notes
– Maintenance-free; no batteries required.
– The O
2
– Do not open the O
3.
Product performance
The O
simulator 82 is connected to the transmitter with a cable instead of the
2
METTLER TOLEDO O
The following adjustments are simulated with the O
Display on
O
simulator
2
Button released
Button pressed
4.
Preparation
Connect the O
5.
Operation
Test the function of the transmitter and of the connecting cable with the following
procedures:
a)
Simulator button pressed:
ponds to:
– 67 nA sensor current (polarization voltage -675 mV)
– 50 nA sensor current (polarization voltage -500 mV)
b)
Simulator button released:
The transmitter display must switch to the stable value of 0.0 ± 0.1 in
less than 10 seconds if the transmitter is calibrated to «zero».
If the value does not stabilize within 10 seconds, change the connecting cable
and repeat the test. If the test still shows the same result, the transmitter is defec-
tive.
To identify the correct function of the transmitter calibration procedure, perform an
additional test:
c)
Switch transmitter to «0» or «zero» and set the zero point, if possible.
d)
Select transmitter range for air calibration, do not press simulator button:
The display on the transmitter should remain at the value obtained in
step c).
e)
Press simulator button:
The display on older types of transmitters must be adjustable with
«Balance» or «Slope» in accordance with the instructions of your
transmitter. With recent transmitter models, slope will be calibrated au-
tomatically.
6.
Product specification
Designation:
Order No.:
Housing:
7.
Glossary
Air value:
O
Simulator 82
2
Instruction manual
Bedienungsanleitung
Instructions d'utilisation
59 906 003 B
simulator is not yet approved for use in explosion-hazard rooms.
simulator.
2
sensor.
2
Simulated input current I E
PV *) -675 mV
0 nA
67 nA
simulator 82 to the transmitter via the standard connecting cable.
2
The transmitter displays a random value > 0, which corres-
PV *) -500 mV
0 nA
50 nA
*) PV = Polarization voltage
O
simulator 82
2
59 906 816
Nickel-plated brass
O
concentration of air in any unit which is set at
2
the transmitter when calibrated.
ISO
ISO
9001
14001
certified
certified
Management System
certified according to
ISO 9001 / ISO 14001
English
transmitter
2
sensor.
2
simulator 82:
2
Simulated value
Nitrogen N
Air value
2