4.3 SAFE INPUT CONNECTIONS
If the Fail Safe safety device is enabled (parameter that can be set in programming level 2), the negative
used for managing the SAFE input is - OUT (see Fig. 13).
o 1=01
SP=01
Other safety
devices
- OUT
If the Fail Safe safety device is disabled (parameter that can be set in programming level 2), the negative
used for managing the SAFE input is -
o 1=00
SP=01
Other safety
devices
-
In case N.C. contact devices are not used (other safety devices) the SAFE input must be jumpered to -OUT
with FAIL SAFE enabled or to GND with FAIL SAFE disabled.
E721
Other safety
OPEN A
GND
- OUT
OPEN B / CLOSE
SAFE
/ STOP
FSW OP
GND
FSW CL
+24V
(see Fig. 14).
OPEN A
GND
OPEN B / CLOSE
SAFE
/ STOP
FSW OP
GND
FSW CL
+24V
7
FAIL SAFE function enabled
o 1=01
Ob=02
devices
FAIL SAFE function disabled
o 1=00
Ob=02
Other safety
devices
-
OPEN A
GND
SAFE
/ OPEN B / CLOSE
STOP
FSW OP
GND
FSW CL
+24V
OPEN A
GND
SAFE
/ OPEN B / CLOSE
STOP
FSW OP
GND
FSW CL
+24V
532014 - Rev. D