2
Erasing the memory
Using this function all programmed information
in the Bewacom can be erased and the unit set
back to factory defaults.
1�
Set Bewacom to programming mode.
2�
Open the Bewacom and turn it around so
the circuit board can be seen.
3�
Press the SW1 button (see the wiring dia-
gram on page 10).
4�
Press 112186 on Bewacom's keypad.
5�
Press 112186 again.
Bewacom now has the default settings:
Password:
Opening time:
Calling time:
Door release from telephone: 0
Background lighting:
Internal sounder:
Possibility to call into Bewa-
com:
Hotline:
Extended opening time:
Extended calling time
BM3 Installation & User Manual
112233
7 seconds
30 seconds
ON
ON
OFF
OFF
OFF
OFF